ELG-150-48A - Hikvision - 84-150W LED Driver a erogazione di potenza e voltaggio costanti - In metallo

ELG-150-48A - Hikvision - 84-150W LED Driver a erogazione di potenza e voltaggio costanti - In metallo
CERCHI ASSISTENZA O UN INSTALLATORE?
-35%

L'ELG-150-48A di Hikvision, è un Driver LED, a voltaggio costante ed erogazione costante, con corpo in metallo e funzione PFC integrata - Protezione IP65 / IP67 - Uscita regolabile via potenziometro - 84-150W - Dimming 3 in 1 - Smart Timer Dimming - Longevità tipica: 50.000 ore - Garanzia 5 anni del produttore - Consumo a riposo / in standby inferiore a 0.5W.



Riferimento: ELG-150-48A

Marca: Hikvision

164,94 €

253,76 € -35%
tasse incluse
IVA incl.
 Su ordinazione in 5 giorni
 dal


hikvision_banner.jpg

HIKVISION - ELG-150-48A - LED DRIVER - 84-150W - POTENZA E VOLTAGGIO COSTANTI - IP65 - IP67

Hikvision
 
HIKVISION - ELG-150-48A 
LED Driver a voltaggio e potenza costanti - 84-150W - Consumo inferiore a 0.5 in condizioni di standby - Corpo realizzato in metallo -  Protezione IP65/IP67 ideale per utilizzo in outdoor - Funzione PFC integrata - Dimming 3in1 - Smart Timer Dimming - DALI - Uscita di potenza DC ausiliaria - Temperatura di funzionamento da -40 a 90°C - Garanzia 5 anni del produttore - Design senza ventola - 100-305VAC - Ideale per illuminazione LED di strade, siti architettonici, spiagge, corsi di fiume - Umidità relativa: 20 ~ 95% RH non-condensing - DC Voltaggio: 48V - Input Frequency Range: 47 ~ 63Hz - HIKVISION - ELG-150-48A
 
 

Dettagli prodotto

  • HIKVISION - ELG-150-48A
  • LED Driver a voltaggio e potenza costanti
  • 84-105W
  • Corpo in metallo
  • Protezione IP65/IP67 per utilizzo in esterni
  • Ideale per l'illuminazione LED di ambienti quali strade, strutture e costruzioni architettoniche, baie, corsi di fiumi
  • Temperatura di funzionamento da - 40 a +90°C
  • 100-305VAC
  • Consumo in standby inferiore a 0.5W
  • 5 anni di garanzia forniti dal produttore
  • Durata di vita tipica 50.000 ore
  • Dimming 3in1, Smart Timer Dimming, DALI
  • Uscita di potenza ausiliaria DC

Scheda tecnica

MODEL

ELG-150-48A

OUTPUT

DC VOLTAGE

48V

CONSTANTCURRENTREGION Note.2

24 ~ 48V

RATED CURRENT

3.13A

RATEDCURRENT(forBETypeonly)

2.8A

RATED POWER

 

(For All the Types)

100VAC ~ 180VAC

105W

200VAC ~ 305VAC

(ExceptforBEType)

150.2W

(For BE Type only)

134.4W

RIPPLE & NOISE (max.) Note.3

250mVp-p

VOLTAGE ADJ. RANGE

Adjustable for A/AB-Type only (via the built-in potentiometer)

43.2 ~ 52.8V

CURRENT ADJ. RANGE

Adjustable for A/AB-Type only (via the built-in potentiometer)

1.56 ~ 3.13A

VOLTAGE TOLERANCE Note.4

±2.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±0.5%

AUXILIARY DC OUTPUT

Nominal 15V(deviation 11.5~15.5V)@0.3A for BE-Type only

SETUP, RISE TIME

Note.6

1600ms, 80ms/115VAC

500ms, 100ms/230VAC

HOLD UP TIME (Typ.)

10ms/115VAC, 230VAC

INPUT

VOLTAGE RANGE

Note.5

100 142 ~ 431VDC 305VAC (Please refer to "STATIC CHARACTERISTIC" section)

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF?0.97/115VAC, PF?0.95/230VAC, PF?0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

TOTAL HARMONIC DISTORTION

THD< 20%(@load?50%/115VC; @load?60%/230VAC; @load?75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)

EFFICIENCY (Typ.)

90%

EFFICIENCY (Typ.)(forBEType only)

88%

AC CURRENT

1.7A / 115VAC

0.9A / 230VAC

0.7A/277VAC

INRUSH CURRENT (Typ.)

COLD START 65A(twidth=550μs measured at 50% Ipeak) at 230VAC ; Per NEMA 410

MAX. No. of PSUs on 16A CIRCUIT BREAKER

3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.75mA / 277VAC

NO LOAD / STANDBY POWER CONSUMPTION

No load power consumption <0.5W for Blank / A / Dx / D2-Type Standby power consumption <0.5W for B / AB / DA-Type

PROTECTION

OVER CURRENT

95 ~ 108%

Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

54 ~ 62V

Shut down output voltage, re-power on to recover

OVER TEMPERATURE

Shut down output voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.

Tcase=-40 ~ +90? (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)

MAX. CASE TEMP.

Tcase=+90?

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80?, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/? (0 ~ 60?)

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS

UL8750(type”HL”)(except for BE-type), CSA C22.2 No. 250.13-12; IEC/EN/AS/NZS 61347-1,IEC/EN/AS/NZS 61347-2-13 independent, EN62384,BIS IS15885(for 12/12B/12DA/24/24B/24DA/36A/42/42A/48A/54 only), EAC TP TC 004,GB19510.1,GB19510.14; IP65 or IP67; KC61347-1,KC61347-2-13 approved

DALI STANDARDS

Compliance to IEC62386-101,102,207 for DA-Type only

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25?/ 70% RH

EMC EMISSION

CompliancetoEN55015,EN61000-3-2 ClassC(@load?60%);EN61000-3-3;GB17743,GB17625.1,EACTPTC020;KCKN15,KN61547

EMC IMMUNITY

CompliancetoEN61000-4-2,3,4,5,6,8,11;EN61547,lightindustrylevel(surgeimmunityLine-Earth6KV,Line-Line4KV),EACTPTC020 ;KCKN15,KN61547

OTHERS

MTBF

899.8K hrs min. Telcordia SR-332 (Bellcore)

313.66Khrs min. MIL-HDBK-217F (25?)

DIMENSION

219*63*35.5mm (L*W*H)

PACKING

0.95Kg ; 16pcs/16.0kg/0.77CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25? of ambient temperature.

2. Please refer to "DRIVING METHODS OF LED MODULE". For DA-Type, Constant Current region is 60%~100% of maximum voltage under rated power delivery.

3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

4. Tolerance : includes set up tolerance, line regulation and load regulation.

5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTICS” sections for details.

6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increaseof the set up time.

7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC}, is about 80? or less.

9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.

10. The ambient temperature derating of 3.5?/1000m with fanless models and of 5?/1000m with fan models for operating altitude higher than 2000m(6500ft}.

11. For any application note and IP water proof function installation caution, please refer our user manual before using.

https://www.meanwell.com/Upload/PDF/LED_EN.pdf

Ulteriori dettagli

Nessun dettaglio aggiuntivo

Download

Depliant in inglese.
Tutti i nostri prodotti sono conformi alla normativa CE vigente (leggi qui). Per richiedere la copia del certificato compila questo modulo

Domanda (0)

Non ci sono domande dei clienti per il momento.


La tua domanda è stata inviata con successo il nostro team. Grazie per la domanda!
Fai una domanda
nascondere la forma
Captcha