60832.175.WH1 # 60832 | Ajax FireProtect 2 AC (Heat/Smoke) Jeweller white is a professional mains-powered fire detector designed to provide continuous and highly reliable protection against fires in residential and commercial premises. The device integrates a dual-spectrum optical smoke sensor with HazeFlow 2 algorithm and dual high-precision A1R heat sensors , capable of detecting real smoke and critical temperature increases while reducing false alarms. 110–240 V power supply with a sealed backup battery , stable Jeweller radio communication up to 1700 m and intelligent interconnected fire alarms ensure operation even in the event of a power outage. The elegant black design, built-in 85 dB siren , continuous self-diagnosis and quick installation make the device ideal for advanced and highly reliable security systems. Ajax
Artikel-Nr.: 60832.175.WH1
Marke: Ajax Systems
EAN: 4823114047053
Disponibilità: 1
TOTALER AUSVERKAUF ×
CLEARANCE SALE!
Take advantage of our must-see outing offers.
Discover the promo >>
60832.175.WH1 | WIRELESS GRID-POWERED SMOKE AND HEAT FIRE DETECTOR

The Ajax FireProtect 2 AC (Heat/Smoke) Jeweler, 60832.175.WH1 , white, is a professional mains-powered fire detector designed to provide continuous and reliable fire protection in residential and commercial environments. It combines advanced Ajax technologies for fast and accurate smoke and overheating detection, ensuring instant notifications and continuous operation even during power outages. Its modern black design, automatic self-diagnosis, and full integration with the Ajax system make it ideal for permanent, high-security installations.
Main specifications:
- Dual-spectrum optical smoke sensor with HazeFlow 2 algorithm for false alarm reduction
- Dual high-precision A1R heat sensors for critical temperature detection
- 110–240 V mains power with sealed battery backup
- Two-way Jeweler radio communication with a range of up to 1700 m
- Intelligent interconnected fire alarms with primary and fallback modes
- Built-in 85 dB siren, status LED and continuous self-diagnosis
Further details
Technical data sheet
| 60832.175.WH1 | |
| Communication | |
| Jeweler communication technology | Proprietary wireless communication technology to transmit commands, alarms, and events. Key features:
|
| Radio frequency bands | 866.0 - 866.5 MHz 868.0 - 868.6 MHz 868.7 - 869.2 MHz 905.0 - 926.5 MHz 915.85 - 926.5 MHz 921.0 - 922.0 MHz Depence on the sales reaction |
| Maximum effective radiated power (ERP) | up to 20 mW Automatic power control to reduce power consumption and radio interference. |
| Radio signal modulation | GFSK |
| Radio signal range | Up to 1,700 m up to 5,500 ft Between the detector and a hub (or radio signal range extender) in an open space. |
| Encrypted radio communication | All the data stored and transmitted are protected by block encryption featuring a dynamic key. |
| Frequency hopping | To prevent radio interference and jamming |
| Sensitive elements | heat sensor heat sensor |
| Dangerous temperature detection | |
| Sensitive element | according to the requirements for Class A1 heat detectors Requirements of EN 54-5 and BS 5446-2 standards |
| High temperature alarm | at temperatures above 64 °C at temperatures above 147 °F |
| Temperature spike alarm | when the temperature rises more than 10°C 50°F in 1 minute or less |
| Smoke detection | |
| Sensitive element | dual-spectrum optical sensor Detects smoke by the size of particles in the air. |
| Protection from false alarms | Does not react to water vapor. |
| Patented smoke chamber | Protects the smoke sensor from dust, dirt, and insects. |
| Additional features | |
| Built-in siren | 85 dB volume at a distance of 3 meters 85 dB volume at a distance of 9 ft Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables the notification. |
| Interconnected fire detectors alarm | via primary interconnection If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps. via fallback interconnection1 At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub. 1 Fallback interconnected alarm is available only for FireProtect 2 detectors with firmware version 5.59.2.ХХ or later. Devices that support the fallback interconnected alarm are marked on the package with a “Fallback interconnect supported” label. |
| LED indication | green is a power indication A LED indicator on the device enclosure lights up once every 56 seconds. The indication meets the requirements of EN 50291 yellow is an indication of malfunctions A LED indicator on the device enclosure lights up when malfunctions are detected. For example, in the case of discharged batteries, contamination of the smoke chamber, or end of the service life red is an indication of fire alarms A LED indicator on the device enclosure lights up when the detector registers a fire alarm |
| Button on the front panel of the detector | In normal mode, when pressed, it starts the smoke chamber test. In the event of an alarm or malfunction, pressing turns off the detector sound notification. |
| External power supply | 110–240 V~, 50/60 Hz The phase and neutral cables from the external power supply should be connected to the WAGO terminals on SmartBracket mounting panel. To remove the detector from SmartBracket, there is no need to disconnect the power cables. |
| Recommendations | The device is designed only for indoor installation SmartBracket mounting panel allows adjusting the position of the detector after installation. |
| Sabotage protection | |
| Tampering alarm | Alerts of attempts to detach the detector from the surface or remove the mounting panel. |
| Protection against spoofing | device authentication |
| Detection of communication failure | within 15 minutes The time to detect communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweler or Jeweller/Fibra settings). The polling interval is fixed at 300 seconds. |
| Power supply | |
| Main | 110–240 V~, 50/60 Hz Up to 2W of mains power consumption. |
| Backup | 1 non-replaceable lithium battery Allows the detector to operate autonomously without the main power source. |
| Enclosure | |
| Color | White |
| Dimension | 122 × 122 × 54 mm 4.80″ × 4.80″ × 2.13″ |
| Weight | 318 g 11.22 oz |
| Operating temperature range | from 0 °C to +50 °C from 32°F to 122°F |
| Operating humidity | up to 80% |
| Complete set | FireProtect 2 AC (Heat/Smoke) Jeweller SmartBracket mounting panel WAGO 221 3-conductor terminal — 2 pcs. (pre-installed in SmartBracket) Installation kit Quick start guide |
| Warranty | 24 months |