DS-PA502-64 - AX Hybrid PRO G2 is a professional intrusion control panel designed for wired and hybrid security systems, with management of up to 64 zones, 64 outputs and 32 areas . It supports dual RS-485 bus with up to 32 devices per bus, as well as keypads, expanders, wireless receivers and dedicated power supplies. It integrates 10/100 Mbps LAN and 2.4 GHz Wi-Fi connectivity, with optional PSTN, GPRS and 4G/LTE modules, dual-path notifications to ARC and ISUP, SIA DC-09, Contact ID and OTAP protocols. It also offers video verification of up to 4 1080p channels , 256 automation scenarios, management of up to 100 operators and 4950 recordable events. Compliant with the EN 50131 Grade 2 standard, it represents a complete and scalable solution for professional alarm systems and advanced security infrastructures. Hikvision
DS-PA502-64 – HYBRID INTRUSION CONTROL PANEL - 64 ZONES

The Hikvision DS-PA502-64 AX Hybrid PRO G2 is a professional intrusion control panel designed for wired and hybrid security systems, with management of up to 64 zones, 64 outputs and 32 areas . It supports dual RS-485 bus with up to 32 devices per bus, up to 16 keypads, expanders, wireless receivers and 256 automation scenarios. It integrates 10/100 Mbps LAN and 2.4 GHz Wi-Fi , with optional PSTN, GPRS and 4G/LTE modules, as well as dual-path communication towards ARC. The control panel offers video verification of up to 4 1080p channels , support for 32 network cameras, 4950 event recordings and management of up to 100 operators . Compatible with ISUP, SIA DC-09, Contact ID, CSV-IP and OTAP protocols, it complies with the EN 50131 Grade 2 standard for professional security applications.
Main features:
- Zones/Exits: 64 / 64
- Areas: 32
- Bus: dual RS-485
- Connectivity: LAN and Wi-Fi
- Optional modules: PSTN, GPRS, 4G/LTE
- Video verification: 4 channels 1080p
- Automations: 256 scenarios
- Users: up to 100 operators
- Standard: EN 50131 Grade 2
Further details
It supports up to 32 independent areas , allowing you to divide and organize the intrusion system into multiple sectors for flexible management of residential, commercial and professional environments.
It can be expanded with GPRS DS-PC501G, 4G/LTE DS-PC502S and PSTN DS-PM2-P communicators, increasing communication possibilities and ensuring greater flexibility in the transmission of alarm events.
It allows the management of 1 administrator, 1 installer and up to 100 operators , as well as 64 Cloud users, 64 remote controls and 100 tags for structured and scalable system access control.
Technical data sheet
| DS-PA502-64 | |
| Inputs (Zones) | |
| Max. Zones | 64 |
| On-board zones | 8 |
| Bus PIR cameras | 24 |
| Outputs | |
| Max. outputs | 64 |
| On-board PGM outputs | 2 |
| On-board relay outputs | 2 |
| Auxiliary Power Output | 1 |
| On-board sounder output | 1 |
| Areas | |
| Area | 32 |
| Peripherals | |
| Keypads | 16 |
| 8-zone expanders | 8 |
| 8-relay expanders | 16 |
| Wireless receivers | 8 |
| Power supply units | 15 |
| Video verification | |
| Network camera channels |
32 |
| Video verification network camera channels |
Up to 4 (1080p) |
| Video verification clip duration |
7 seconds |
| Pre-record |
2 or 5 seconds |
| Programming | |
| Automation scenarios | 256 |
| Event Log | |
| Event log records | 4950 including 1000 mandatory in flash memory |
| User | |
| Admin | 1 |
| Installer | 1 |
| Max. operators | 100 |
| User (Cloud) | 64 |
| Authorization devices | |
| Keyfobs |
64 |
| Tags |
100 |
|
Bus interconnection |
|
| Bus ports | 2 |
| Bus technology | Half-Duplex RS-485 |
| Bus wiring | 4-Core Alarm Cable (at least 2 × 0.5 mm² + 2 × 0.22 mm²) |
| Bus topologies | Daisy Chain, Cascade, Star, Ring |
| Range per Bus | Up to 500m (Up to 7.5km with bus-extenders, Up to 4km in loop mode, Up to 1km in compatible mode) |
| Bus extenders for buses | Up to 15 pcs, 500m in between |
| Devices per Bus | 32 |
| Communication interfaces | |
| LAN/Ethernet | 10/100 Mbps self-adaptive |
| Wi-Fi | 802.11b/g/n (2.4GHz) |
| GPRS | Compatible with DS-PC501G(Optional) |
| 4G/LTE | Compatible with DS-PC502S (Optional) |
| PSTN | Compatible with DS-PM2-P(Optional) |
| ARC connectivity | |
| ARCs | 4 |
| Signaling protocols | ISUP, Contact ID(PSTN), SIA DC-09, CSV-IP, OTAP |
| Ack. operation | Pass-through |
| ATS Categories | SP3, DP2 (with optional GPRS/4G communicator) |
| 3rd party communicator | Compatible with FSK, RDC, IDS modules |
| Power supply - general | |
| PS type | Type A |
| Quiescent current | 130 mA @15VDC (when on battery) |
| Power supply - primary power supply | |
| Mains Input | 100-240VAC 50/60Hz, 0.3A |
| Power supply capacity | 15.3 VDC 2.5 A (0.5 A dedicated to battery) |
| Power supply - auxiliary power supply | |
| Battery pack | 1 × rechargeable sealed lead-acid (SLA) battery (not included by default) |
| Battery capacity | 12VDC, up to 7Ah (≥ 5600 mAh in charged state) |
| Recommended battery | OUTDO OT7-12 (7Ah), Yuasa NP7-12FR (7Ah) |
| Battery standby | Up to 12 hours |
| Recharge period | 24 hours to 80% (5600 mAh) |
| Floating voltage | 13.8VDC |
| Low energy voltage | 11.60±0.5 V (Restore when rise above 11.74±0.5 V) |
| Cut-off voltage | 11.0 VDC for deep-discharge protection |
| Power supply - auxiliary power output | |
| Output capacity | Nominal 14.5VDC 1.5A, range 10.7-15 VDC with up to 120 mV ripple (Vpp) |
| Output protection | 1.7 A resettable eFuse |
| Power supply - bus power output | |
| Output capacity | Nominal 14.5VDC, range 10.7-15 VDC with up to 120 mV ripple (Vpp), max. 20W (shared AUX power output) |
| Output protection | (Shared AUX power output) |
| Power supply - sounder power output | |
| Output capacity | Nominal 14.5VDC 1.0A, range 10.7-15 VDC with up to 120 mV ripple (Vpp) |
| Output protection | 1.3 A resettable eFuse |
| PGM output | |
| Output capacity | 0 VDC with switched (NPN output) |
| Max. current | 200 mA per output |
| Relay output | |
| Relay output | 3A 30VDC, 1A 250VAC |
| Environmental | |
| Operating temperature | -10°C to 50°C (14°F to 122°F), indoor use only |
| Storage temperature | -20°C to 60°C (-4°F to 140°F) |
| Relative humidity | 10% ~ 90% non-condensing |
| Physical | |
| Dimensions (W × H × D) | 231 × 133 × 44 mm |
| Weight | 488 g |
| Compliance | |
| Electrical compliance | CE, CB |
| EN 50131 | Security Grade 2, Environmental Class II |